Landtec GEM 5000 Plus Landfill Gas Monitor Rental
Landtec GEM 5000 Plus Landfill Gas Monitor Rental
- Measures methane (0-100%), carbon dioxide (0-100%), oxygen (0-25%), carbon monoxide (0-2000ppm), hydrogen sulfide (0-500ppm), static pressure and differential pressure
- Calculates balance gas, flow (SCFM) and calorific value (KW or BTU)
- High Accuracy and Fast Response Time
- Certified intrinsically safe for landfill use
Accessories
The GEM™5000 is designed specifically for use on landfills to monitor Landfill Gas (LFG) Collection & Control Systems. The GEM™5000 samples and analyzes the methane, carbon dioxide and oxygen content of landfill gas with options for additional analysis.
The GEM5000 measures flow and calculates the calorific values of the gas as well as being a useful tool for balancing the gas field. The GEM5000 gas analyzer may be used to monitor, calculate, adjust and record the flow at each monitoring point. This instrument may also be used in GA (gas analyzer) mode of operation if required. The operator may change the analyzer between a gas extraction monitor (GEM mode) or a landfill gas analyzer (GA Mode).
Sensor | Range |
---|---|
Methane | 0 - 100% |
Carbon Dioxide | 0 - 100% |
Oxygen | 0 - 25% |
Carbon Monoxide | 0 - 2000 ppm |
Hydrogen Sulfide | 0 - 500 ppm |
Detection Principle |
|
Accuracy | |||
---|---|---|---|
CH4 | 0-5% ± 0.3% (vol) | 0-70% ± 0.5% (vol) | 70-100% ± 1.5% FS |
CO2 | 0-5% ± 0.3% (vol) | 0-60% ± 0.5% (vol) | 60-100% ± 1.5% FS |
O2 | 0-25% ± 1.0% (vol) | ||
CO | 0-2000ppm ± 1.0% FS | ||
H2S | 0-500ppm ± 2.0% FS | ||
Other Parameters | Unit | Resolution | Comments |
Energy | BTU/hr | 1000 BTU/hr | Calculated from specific parameters |
Static Pressure | in. H2O | 0.1 in. H2O | Direct Measurement |
Differential Pressure | in. H2O | 0.001 in. H2O | Direct Measurement |
Sampling Pump | Flow Typically 550 cc/min |
---|---|
Flow w/ 80 In. H2O vacuum | Approx. 80 cc/min |
Battery life | Typical use 8 hours from fully charged |
Charge time | Approximately 3 hours from complete discharge. |
Operating Temperature Range | 14°F - 122°F (-10°C to +50°C) |
Operating Pressure | -100 In. H2O, +100 in. H2O (-250mbar, +250mbar) |
Relative Humidity | 0-95% non condensing |
Barometric Pressure | ± 14.7 in.Hg (±500mbar) from calibration pressure |
Barometric Pressure Accuracy | ± 1% typically |
ATEX | II 2G Ex ib IIA T1 Gb (Ta= -10°C to +50°C) |
ISO17025 | ISO/IEC17025:2005 Accreditation #66916 |
CSA | Ex ib IIA T1 (Ta= -10°C to +50°C) (Canada), AEx ib IIA T1 (Ta= -10°C to +50°C) USA |
- GEM 5000
- Data Cable
- PVC Tubing
- Hard Carrying Case
- Soft Case with Strap
- Instruction Manual
- Water Trap Filter with Tubing
- Battery Charger
- LANDTEC System Gas Analyzer Manager Software
- Field Calibration Record
- Factory Calibration Certificate
- Spare Filter