RAE Systems ppbRAE Plus PID
RAE Systems ppbRAE Plus PID
- Measures VOCs 1 ppb to 2,000 ppm.
- Exclusive zeroing tube, assures repeatability at low-level measurements.
- Drop-in battery, over 10 hours of use per charge
- Strong, built-in sampling pump, draws up to 100 feet.
Hand-held PID Monitor Capable of Detecting VOCs in the Parts-Per-Billion (ppb) Range
The most sensitive handheld VOC monitor in the world with true parts per billion (ppb) detection of extremely low level, low vapor pressure and highly toxic Volatile Organic Compounds (VOCs) such as nerve agent, pesticide residues and low level permeation breakthrough detection.
Range | Resolution | Response Time T90 |
---|---|---|
0 to 9999 ppb | 1 ppb | < 5 sec |
10.0 to 99.9 ppm | 0.1 ppm | < 5 sec |
100 to 200 ppm | 1 ppm | < 5 sec |
Size | 8.2" L x 3.0" W x 2.0" H (21.8 x 7.62 x 5.0 cm) |
Weight | 19.5 oz with battery pack (553 g) w/o rubber boot |
Sensors | Patented, planar, dual-channel, photoionization sensor with super-bright 10.6 eV lamp |
Battery | Rechargeable, external, field-replaceable Nickel-Metal- Hydride (NiMH) battery pack |
Operating Hours | 10 hours continuous operation |
Display | Large LCD, backlight activated manually, by alarms or by darkness |
Keypads | 1 operation and 2 programming keys |
Direct Readout |
|
Alarms |
|
EM/RFI | Highly resistant to EMI /RFI. Compliant with EMC Directive 89/336/EEC |
IP Rating | IP-55: protected against dust, protected against low-pressure jets of water from all directions |
Data Logging | 267 hours (at one-minute intervals) with date/time. Header information includes monitor serial number, user ID, site ID, date and time |
Calibration | Two-point field calibration of zero and standard reference gas. Calibration memory of 8 calibration gases, alarm limits, span values and calibration date |
Sampling Pump |
|
Low Flow Alarm | Auto shut-off pump at low flow condition |
Communications | Download data and upload instrument set-up from PC through RS-232 link to serial port. |
Frequency | 902 to 928 MHz (license-free), 2.400 to 2.4835 GHz (license-free), 433 MHz, 869 MHz |
Hazardous Area Approval |
|
Temperature | 14° F to 104° F (-10° C to 40° C) |
Humidity | 0% to 95% relative humidity (non-condensing) |
Attachment | Durable bright black rubber boot w/ belt clip & wrist strap |
Images | Part # | Title | Categories | Price |
---|---|---|---|---|
500-0036-100 | AC Charger Adapter | AC Charger | Quote | |
002-3022-005 | External Filters (Pack of 5) | Filter | Quote | |
002-3022-010 | External Filters (Pack of 10) | Filter | Quote | |
002-3022-100 | RAE Systems External Filters (Pack of 100) | Filter | Quote |