RAE Systems Chlorine Dioxide Sensor C03-0956-000
RAE Systems Chlorine Dioxide Sensor C03-0956-000
| Sensor Type | Electrochemical |
| Range | 0 to 1 ppm |
| Resolution | 0.01 ppm |
| Bias/Equilibration | No bias / 10 min. after installation |
| Temperature Range | -4° F to 104° F (-20° C to 40° C) |
| Pressure Range | Atmospheric ±10% |
| Operating Humidity | 5 to 90% RH non-condensing |
| Drift | < 5% signal / 6 months |
| Temperature Effect | < 0.02 ppm increase from -4° F to 104° F |
| Storage Life | 6 months in sealed container |
| Storage Temperature | 32° F to 68° F (0° C to 20° C) |
| Operating Life | 2 years from date of shipment |
| Warranty | 1 year from date of shipment |
| Calibration Gas | 0.8 CLO2 from gas generator (requires CLO2 gas generator or quarterly factory calibration) |