RAE Systems ppbRAE Plus PID Rental

  • Measures total volatile organic compounds (VOCs) in parts per billion (1 ppb to 2,000 ppm).
  • 267 hours (at one-minute intervals) datalogging storage capacity.
  • Correction factors for more than 100 compounds.
  • Built-in sample pump 400 cc/min, draws 100 feet (30m) horizontally or vertically.

Discontinued

We no longer offer this product.

If available, alternative products will be listed below.

Hand-held PID Monitor Capable of Detecting VOCs in the Parts-Per-Billion (ppb) Range. The most sensitive handheld VOC monitor in the world with true parts per billion (ppb) detection of extremely low level, low vapor pressure and highly toxic Volatile Organic Compounds (VOCs) such as nerve agent, pesticide residues and low level permeation breakthrough detection.

Range Resolution Response Time T90
0 to 9999 ppb 1 ppb < 5 sec
10.0 to 99.9 ppm 0.1 ppm < 5 sec
100 to 200 ppm 1 ppm < 5 sec
Size 8.2" L x 3.0" W x 2.0" H (21.8 x 7.62 x 5.0 cm)
Weight 19.5 oz with battery pack (553 g) w/o rubber boot
Sensors Patented, planar, dual-channel, photoionization sensor with super-bright 10.6 eV lamp
Battery Rechargeable, external, field-replaceable Nickel-Metal- Hydride (NiMH) battery pack
Operating Hours 10 hours continuous operation
Display Large LCD, backlight activated manually, by alarms or by darkness
Keypads 1 operation and 2 programming keys
Direct Readout
  • VOCs as ppb or ppm by volume
  • High and low values
  • STEL and TWA (in hygiene mode)
  • Battery and shut down voltage
Alarms
  • High: 3 beeps and flashes per second
  • Low: 2 beeps and flashes per second
  • STEL and TWA: 1 beep and flash per second
  • Alarms automatic reset or latching with manual override
  • Optional plug-in pen size vibration alarm
  • User adjustable alarm limits
EM/RFI Highly resistant to EMI /RFI. Compliant with EMC Directive 89/336/EEC
IP Rating IP-55: protected against dust, protected against low-pressure jets of water from all directions
Data Logging 267 hours (at one-minute intervals) with date/time. Header information includes monitor serial number, user ID, site ID, date and time
Calibration Two-point field calibration of zero and standard reference gas. Calibration memory of 8 calibration gases, alarm limits, span values and calibration date
Sampling Pump
  • Internal, integrated flow rate of 400 cc/min
  • Sample from 100' (30 m) horizontally or vertically
Low Flow Alarm Auto shut-off pump at low flow condition
Communications Download data and upload instrument set-up from PC through RS-232 link to serial port.
Frequency 902 to 928 MHz (license-free), 2.400 to 2.4835 GHz (license-free), 433 MHz, 869 MHz
Hazardous Area Approval
  • US and Canada: UL and cUL, Classified for use in Class I, Division 1, Groups A, B, C and D hazardous locations
  • Europe: ATEX II IG EEx ia IIC T4
Temperature 14° F to 104° F (-10° C to 40° C)
Humidity 0% to 95% relative humidity (non-condensing)
Attachment Durable bright black rubber boot w/ belt clip & wrist strap
  • ppbRAE+ PID
  • Data Download Cable
  • Instruction Manual
  • Hard Case
  • Charcoal Zero Adapter
  • Battery Charger
  • Calibration Record
  • ProRAE Suite Software
  • Spare Filter