Environmental Monitoring Equipment & Supplies • Sales, Rental & Service by Enviro-Equipment — Charlotte, North Carolina USA

  • Measures total volatile organic compounds (VOCs) in parts per billion (1 ppb to 10,000 ppm).
  • Humidity compensation with integral humidity and temperature sensors.
  • 260,000-point datalogging storage capacity
  • Correction factors for more than 200 compounds.
  • Built-in sample pump 450-550 cc/min, draws 100 feet (30m) horizontally or vertically.
Title Daily Rate Weekly Rate Monthly Rate
RAE Systems ppbRAE 3000 PID (10.6 eV) Rental $120.00 $375.00 $1,115.00

The RAE Systems ppbRAE 3000 photoionization detector (PID) is a hand held volatile organic compound (VOC) detector that measures VOC levels as low as 1 ppb and up to 10,000 ppm. The monitor can log up to 6 months of data at one-minute intervals. The ppbRAE 3000 has a built-in humidity and temperature sensor to compensate for humidity levels, improving the accuracy of readings. The instrument comes pre-calibrated to 10 ppm isobutylene by our environmental specialists, and includes a calibration record.

Items Included:
  • ppbRAE 3000 PID
  • USB Data Cable
  • Instruction Manual
  • Hard Case
  • Charcoal Zero Adapter
  • Battery Charger with Cradle
  • Calibration Record
  • ProRAE Studio Software
  • Spare Filter

Range

Resolution

Response Time T90

0-9999 ppb

1 ppb

< 3 s

10-99 ppm

0.01 ppm

< 3 s

100-999.9 ppm

0.1 ppm

< 3 s

1000-9999 ppm

1 ppm

< 3 s

Size

10" L x 3.0" W x 2.5" H (25.5 cm x 7.6 cm x 6.4 cm)

Weight

26 oz (738 g)

Sensors

Photoionization sensor with standard 10.6 eV or optional 9.8 eV or 11.7 eV lamps

Battery

  • Rechargeable, external field-replaceable Lithium-Ion battery pack
  • Alkaline battery adapter

Operating Hours

16 hours of operation (12 hours with alkaline battery)

Display

4 lines, 28 x 43 mm, with LED backlight for enhanced display readability

Keypads

1 operation and 2 programming keys, 1 flashlight on/off

Direct Readout

VOCs as ppm by volume, High values, STEL and TWA, Battery and shutdown voltage, Date, time, temperature

Alarms

95dB at 12" (30 cm) buzzer and flashing red LED to indicate exceeded preset limits:

  • High: 3 beeps and flashes per second
  • Low: 2 beeps and flashes per second
  • STEL and TWA: 1 beep and flash per second
  • Alarms latching with manual override or automatic reset
  • Additional diagnostic alarm and display message for low battery and pump stall

EM/RFI

Highly resistant to EMI/RFI. Compliant with EMC directive (2004/108/EC); R & TTE directive (1999/5/EC)

IP Rating

IP67 unit off and without flexible probe, IP65 unit running

Data Logging

Standard 6 months at one-minute intervals

Calibration

Two-point or three-point calibration for zero and span. Calibration memory for 8 calibration gases, alarm limits, span values and calibration dates

Sampling Pump

Internal, integrated flow rate at 500 cc/mn, Sample from 100' (30m) horizontally and vertically

Low Flow Alarm

Auto shut-off pump at low flow condition

Communications

Download data and upload instrument set-up from PC through charging cradle or optional Bluetooth™. Wireless data transmission through built-in RF modem.

Frequency

902 to 928 MHz (license-free), 2.400 to 2.4835 GHz (license-free), 433 MHz, 869 MHz

RF Range

Up to 500' (152m; 900 MHz, 433 Mhz, 869 Mhz), extendable with RAELink3 Repeater to 2 miles (3.2km)

Hazardous Area Approval

  • US and Canada: Classified as Intrinsically Safe for use in Class I, Division 1 Groups A, B, C, D
  • Europe: ATEX II 2G EEx ia IIC T4

Temperature

-4 to 122 °F (-20 to 50 °C)

Humidity

0% to 95% relative humidity (non-condensing)

Attachment

Durable black rubber boot