Horiba U-22 10-parameter Water Quality Instrument

Simultaneous measurement of 10 Parameters:
  • pH
  • Dissolved Oxygen
  • Conductivity
  • Salinity
  • Total Dissolved Solids
  • Seawater Specific Gravity
  • Temperature
  • Turbidity
  • Depth
  • Oxidation Reduction Potential
  • Rent This Product

    Horiba U-20 Series Water Quality Monitoring System
    Years of Horiba sensor technology development have reached their culmination in the form of a 46-mm diameter sensor probe.  These units offer a compact, highly accurate monitoring solution with high pressure tolerance, long term continuous measurement capabilities, waterproof construction, and monitoring of up to 13 parameters. 
    Features:
    • One Touch Calibration - Just submerge the probe into the calibration beaker filled with standard solution and press the button for simultaneous one-point calibration.  The system also enables two-point calibration where high precision measurement data is required.
    • Probe assembly fits inside 2-inch well. (10m and 30m cable units only)
    • Data Logging Capability - The sensor's built in memory function enables continuous measurement for as long as one month (with measurements every 15 minutes).
    • Simultaneous Measurement of up to 10 Parameters
    • Measurement at Depths up to 30 Meters
    • High-Precision Dissolved Oxygen Sensor - This quick response sensor requires no stirring.
    • System Enables PC, and Printer Capabilities
    • Dry Cell Battery Operated - runs on standard alkaline batteries.

    Product



    Description



     

    Specifications:



     
    Main unit External dimension: 169(H) x 98(W) x 56(D)mm
      Weight: approx 485g
      Water proof construction:  IP- 67
         

    Sensor probe

    Measurement temperature: 

    0-55°c 
      Storage temperature: - 5-60°c
      Measurement depth: to 30m
      Maximum probe size: 46mm 
      Probe length: 380mm 
      Continuous use available: 30days Manual data memory (2880 items) Automatic calibration
      Weight: approx 1500 g(with 10 m cable)
      Probe Length: 380m

    pH
     
    Two - point calibration Automatic temperature compensation 
      Measuring principle: Glass electrode method
      Range: pH0~14 
      Resolution: 0.01pH
      Repeatability: ±0.05pH
      Accuracy: ±0.1pH

    Dissolved oxygen
     
    Salt correction (0 to 40 ppt / automatic) Automatic temperature compensation
      Measuring principle: Diaphragm gavanic 
      Method Range: 0-19.99mg /L
      Resolution: 0.01mg/L
      Repeatability: ±0.1mg/L 
      Accuracy: ±0.2mg/L

    Conductivity
     
    Auto range 
    Automatic temperature conversion)(25°C) SI units
      Measuring principle: 4 AC electrode 
      Method range: 0~4%
      Resolution: 0.01% 
      Repeatability: ±0.1% 
      Accuracy: ±0.3%

    Salinity

    Measuring principle:

    Conductivity
      Conversion range: 0-4%
      Resolution: 0.01%
      Repeatability: ±0.1%
      Accuracy: ±0.3%

    Total Dissolved Solids (TDS)
     
    Conversion factor setting
      Measuring principle: Conductivity
      Conversion range: 0-100mg/L 
      Resolution: 0.1%F.S 
      Repeatability: ±2mg/L 
      Accuracy: ±5mg/L

    Seawater specific gravity
     
    Display Seawater specific gravity Display °t, °0, °15
      Measuring principle: Conductivity
      Conversion range: 0-50°t
      Resolution: 0.1°t 
      Repeatability: ±2°t
      Accuracy:  ±5°t

    Temperature

    Measuring principle:

    Thermistor 
      Method range: 0-55°c
      Resolution: 0.01°c 
      Repeatability: ±0.3°c
      Accuracy: ±1.0°c

    Turbidity

    Unit selection Measuring principle:

    Penetration and scattering
      Method range: 0-800 NTU
      Resolution: 0.1NTU 
      Repeatability: ±3%
      Accuracy: ±5%

    Water depth

    Measuring principle:

    Pressure method range 
    (NTU or mg / L):0-100m
      Resolution: 1m Repeatability: ±3% 
      Accuracy: ±5%

    Oxidization reduction potential(ORP)

    Measuring principle:

    Platinum electrode
      Method range: ±1999mV
      Resolution: 1mV Repeatability:±5mV
      Accuracy:  ±15mV
         
      Notes: The accuracy rating value is obtained from measurements at an intermediate point of the standard solution after two-point calibration (at room temperature andpressure). The repeatability and accuracy rating percentages are based on the full scale (except for salinity).
    • Organic solvents, strong acids, and strong alkaline solvents cannot be measured.
    • The accuracy rating is obtained from measurements at an intermediate point of the standard solution after two-point calibration (at room temperature and pressure).
    • The repeatability and accuracy rating percentages are based on the full scale (except for salinity).
    • Datalogging capabilities are based on data measured automatically at 15 minutes intervals with new alkaline batteries.
    • Periodical electrode maintenance and multi-point calibration is necessary.
     

    » «