CES Landtec GEM-500 Landfill Gas Monitor Rental
Home » Equipment Rentals » Gas Meter Rentals » Landtec Gem 500 Landfill Gas Monitor
|
|
Daily |
Weekly
|
Monthly
|
$155.00 |
$465.00 |
$1,200.00 |
Optional Rental Accessories:
(click pictures to enlarge)
Temperature Probe |
|
Daily |
Weekly |
Monthly |
$5.00 |
$15.00 |
$45.00 |
|
|
Charcoal Filter Adapter |
|
Daily |
Weekly |
Monthly |
$5.00 |
$15.00 |
$45.00 |
|
|
|
|
Daily |
Weekly |
Monthly |
$20.00 |
$60.00 |
$180.00 |
|
*NOTE: All Organic Vapor Analyzers (PID, FID, TLV Sniffer) and Gas Meters are calibrated prior to each rental. If you wish to purchase calibration gas, please call for pricing.
Also, we no longer ship calibration kits for rental since the return shipper must be a certified hazardous materials shipper. Rental rates are based on 25% calibration gas usage per week (based on tank pressure).
Overages will be billed in 25% increments in addition to the rental rate.
Downloads:
Measurement Units and Specifications
| Screen 1 |
|
|
|
Type |
Displayed as |
USA (Imperial) |
Metric (SI) |
Methane |
CH4% |
% by volume |
% by volume |
Carbon Dioxide |
CO2% |
% by volume |
% by volume |
Oxygen |
O2% |
% by volume |
% by volume |
Balance |
BAL |
% by volume |
% by volume |
|
|
|
|
Screen 2 |
|
|
|
Type |
Displayed as |
USA (Imperial) |
Metric (SI) |
Methane |
CH4% |
% by volume |
% by volume |
Lower Explosive Limit |
CH4% LEL |
% of 5% CH4 |
% of 5% CH4 |
|
|
|
|
Screen 3 |
|
|
|
Type |
Displayed as |
USA (Imperial) |
Metric (SI) |
Static Pressure |
SP |
w.c. (H2O) |
mb (millibar) |
Differential Pressure |
DP |
w.c. (H2O) |
mb (millibar) |
Temperature |
T °F/°C |
°F (degrees Fahrenheit) |
°C (degrees Celsius) |
Screen 4 |
|
|
|
Type |
Displayed As |
USA (Imperial) |
|
Old (past) BTU |
BTU OLD |
Per cubic foot |
|
Old (past) BTU |
KJ OLD |
per cubic meter |
|
Old (past) Gas Flow |
scfm Feet std. |
cubic feet per min. |
|
Old (past) Gas Flow |
scfm OLD |
std. cubic meters per min. |
|
Adj. (present) BTU |
BTU ADJ |
per hr |
|
Adj. (present) BTU |
KJ ADJ |
per hr. |
|
Adj. (present) Gas Flow |
scfm ADJ |
std. cubic feet per min. |
|
Adj. (present) Gas Flow |
scfm OLD |
std. cubic meters per min. |
|
|
|
Operating Temperature |
10 to 104°F (-10 to 40°C) |
Range and Resolution
|
Sensor Range Imperial |
Resolution Imperial |
Methane |
0-100% |
0.1 |
Carbon Dioxide |
0-50% |
0.1 |
Oxygen |
0-25% |
0.1 |
Pressure-Differential |
0-10"w.c. |
0.01 |
Pressure-Static |
0-100"w.c. |
0.1 |
Typical Accuracy
|
% Methane |
% Carbon Dioxide |
% Oxygen |
Concentration |
by Volume |
by Volume |
by Volume |
5% (LEL CH4) |
± 0.5% |
± 0.5% |
± 1.0% |
15% (UEL CH4) |
± 1.0% |
± 1.0% |
± 1.0% |
| 100% |
± 3.0% |
± 3.0% |
n/a |