Environmental Monitoring Equipment & Supplies • Sales, Rental & Service by Enviro-Equipment — Charlotte, North Carolina USA

  • Gamma radiation scintillator using 3cc CsI(TI) with Photodiode.
  • Continuous digital readout in μR/h or in μSv/h and counts per second (cps).
  • Direct readout for dose rate, peak rate, min rate, total gamma dose, battery, time/date, and internal temperature.
Title Daily Rate Weekly Rate Monthly Rate
GammaRAE II Personal Gamma Radiation Detector Rental $60.00 $145.00 $375.00

GammaRAE II is the first personal radiation detector (PRD) to provide rapid detection of gamma ray sources even in potentially flammable environments. Certified intrinsically safe and water-immersible for chemical decontamination purposes, the GammaRAE II can be safely used in more environments than any other PRD.

The sensitive Cesium Iodide (CsI) scintillator of the GammaRAE II provides a fast, two-second response to radiological threats. GammaRAE II alerts the wearer with a loud 85+ dB audible alarm, big, bright flashing LEDs, and a vibration alarm. For stealth operations, law enforcement personnel can disable each alarm individually.

The GammaRAE II accumulates approximate dosage. Dosage data stored can be cumulative or cleared and reset for each use period. IS Certification permits operation in potentially flammable/explosive environments.

Items Included:
  • RAE Systems GammaRAE II
  • Spare Batteries
  • User Manual
  • Carrying Case

Size

4.92" x 2.68" x 1.38"

Weight

9 oz. (240g)

Detector

CsI (TI)/Photodiode

Battery

2 AA Alkaline batteries easily accessible with a coin

Operating Period

Up to 800 hours

Display

Graphic LCD display with 1.2" x 0.75" viewable area can be flipped for view by wearer or by others; cps or dosage rate in µR/hr or µSv

Direct Readout

Dosage rate, peak, min, dosage, battery status, time, temp

Alarms

Loud 85 dB @ 12" for noisy environments, Built-in vibration alarm, Highly visible LED lights on both sides of LCD graphic display

Energy Range

0.06 - 3.0 MeV

Sensitivity

More than 1 cps per µR/hr (> 100 cps per µSv/hr)

Dose Equivalent Rate (DER) range for 137Cs

1-4000 µR/h (0.01-40 µSv/h)

Accuracy of DER for 137Cs

±20%

Dosage Range

1 µR - 999 µR

Temperature

-20°C to 50°C (-4°F to 122°F)

Humidity

0% - 93% RH (non-condensing)

IP rating

IP67

Attachments

Rugged metal belt clip and wrist strap; optional nylon pouch with spare battery compartment

Certification

Intrinsically safe; CSA Class I, Division 1, Groups A, B, C, D, T4 US/Canada

AttachmentSize
GammaRAE II Manual576.84 KB
GammaRAE II Training Guide439.36 KB