| Specifications |
3700C Compact Portable Sampler |
| |
|
| Size |
(Diam x Ht): 17 x 27 inches (45 x 70.5 cm) |
| Weight: |
Dry, less battery - 25 lbs (11.3 kg) |
| Material: |
Fiberglass-reinforced plastic with UV-resistant gel coat |
| Power required: |
12 VDC |
| |
|
| |
Pump |
| Intake purge: |
Adjustable air purge before and after each sample. |
Tubing life indicator:
|
Provides a warning to change pump tubing. |
| Pump tubing life: |
Recommended 500,000 pump counts |
| Intake suction tubing: |
Vinyl or Teflon®; 3/8 inch (1 cm) or 1/4 inch (0.6cm) ID; 3 to 99 feet (1 to 30 m) Length |
| Maximum lift: |
26 ft. (7.9 m) |
| Repeatability: |
±10 ml typical |
| Typical line velocity @ Head height: |
2.9 ft./s @ 3 ft; 2.5 ft./s @ 10 ft; 1.9 ft./s @ 15 ft.
(0.88 m/s @ 0.9 m; 0.76 m/s @ 3.1 m; 0.58 m/s @ 4.6 m) |
| Liquid presence detector: |
Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
| |
|
| |
Controller |
| Weight: |
11 lbs (5 kg) |
| Size (HxWxD): |
10 x 12.5 x 10 inches (25 x 32 x 25 cm) |
| Operational temperature: |
32° to 120°F (0° to 49°C) |
| Enclosure rating: |
NEMA 4X, 6 IP67 |
| Program memory: |
Non-volatile ROM |
| Flow meter signal input: |
5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
| Interface port: |
8 pin connector; data output at 2400 baud in ASCII. RS-232 format with handshake. |
| Clock accuracy: |
1 minute per month, typical, for real time clock |
| |
|
| |
Software |
| Sample frequency: |
1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
| Sample pacing: |
Uniform time, non-uniform time, flow, flow paced/time switched, STORM (time and flow paced sampling during sample collection.) Flow pacing is controlled by external flow pulses. |
| Multiplexing: |
Samples per bottle (1 to 50 with 1000 ml bottles, bottles per sample (1 to 24), multiple bottle compositing. |
| Sample volumes: |
Programmable from 10 to 9,990 ml in 1 ml increments |
| Sample retries: |
If no sample is detected, up to 3 attempts; user selectable |
| Rinse cycles: |
Automatic rinsing of suction line up to 3 rinses for each sample collection |
| Program storage: |
3 sampling programs |
| Programming modes: |
Basic, extended and STORM |
| Sampling stop/resume: |
Up to 24 real time/date sample stop/resume commands. |
| Controller diagnostics: |
Tests for RAM, ROM, pump display, and distributor |