Environmental Monitoring Equipment & Supplies • Sales, Rental & Service by Enviro-Equipment — Charlotte, North Carolina USA

MODEL# PGM-1860

  • Over twenty gas sensors available to choose from
  • Intelligent sensors store calibration data, so they can be swapped in the field
  • Continuous datalogging
  • Li-ion battery provides up to 30 hours of use per charge.

The ToxiRAE Pro is the world’s first wireless personal monitor for toxic gases and oxygen. The ToxiRAE Pro takes worker protection to the next level by providing safety professionals wireless access to real-time instrument readings and alarm status from any location for better visibility and faster response. The ToxiRAE Pro can detect a broad range of gases — from carbon monoxide, hydrogen sulfide, and oxygen to ammonia, chlorine, and phosgene. The ToxiRAE Pro’s intelligent interchangeable sensors store calibration data, so if you need to monitor one gas one day and another gas the next, swapping the sensors in your ToxiRAE Pro is all it takes.

Sensor

Range

Resolution

Ammonia (NH3)

0 to 100 ppm

1 ppm

Carbon Monoxide (CO)

0 to 500 ppm

1 ppm

Carbon Monoxide (CO), Ext. Range

0 to 2000 ppm

10 ppm

Carbon Monoxide (CO), H2-Compensated

0 to 2000 ppm

10 ppm

Chlorine (Cl2)

0 to 50 ppm

0.1 ppm

Chlorine Dioxide (CLO2)

0 to 1 ppm

0.03 ppm

Ethylene Oxide (EtO-A)

0 to 100 ppm

1 ppm

Ethylene Oxide (EtO-B)

0 to 10 ppm

0.1 ppm

Ethylene Oxide (EtO-C), Ext. Range

0 to 500 ppm

10 ppm

Hydrogen (H2)

0 to 1000 ppm

2 ppm

Hydrogen Chloride (HCl)

0 to 15 ppm

0.2 ppm

Hydrogen Cyanide (HCN)

0 to 50 ppm

0.5 ppm

Hydrogen Fluoride (HF)

0 to 10 ppm

0.1 ppm

Hydrogen Sulfide (H2S)

0 to 100 ppm

0.1 ppm

Hydrogen Sulfide (H2S) Ext. Range

0 to 1000 ppm

1 ppm

Methyl Mercaptan (CH3-SH)

0 to 10 ppm

0.1 ppm

Nitric Oxide (NO)

0 to 250 ppm

0.5 ppm

Nitrogen Dioxide (NO2)

0 to 20 ppm

0.1 ppm

Oxygen (O2)

0 to 30% Vol.

0.1% Vol.

Phosgene (COCl2)

0 to 1 ppm

0.02 ppm

Phosphine (PH3)

0 to 20 ppm

0.1 ppm

Phosphine (PH3) Ext. Range

0 to 1000 ppm

1 ppm

Sulfur Dioxide (SO2)

0 to 20 ppm

0.1 ppm

Size

118 mm x 60 mm x 30 mm (4.6" x 2.4" x 1.2")

Weight

220g (7.76 oz)

Sensors

Over 20 intelligent interchangeable field-replaceable electrochemical sensors

Battery

Rechargeable Li-ion battery

Display

Operating time > 30 hours (normal operation)

Display Readout

Graphical LCD display with white LED backlighting (activated when monitor is in alarm or with a button press)

Keypads

2 buttons for operation and programming

Sampling

Real-time reading of concentrations in parts per million; battery status; datalogging on/off status; wireless on/off and reception quality; STEL, TWA, and peak values (as applicable)

Calibration

Wireless remote alarm notification, audible (95dB @ 30cm), vibration, visible alarm (flashing bright red LEDs), and on-screen indication of alarm conditions• Additional diagnostic alarm and display message for low battery

Alarm Modes

  • Wireless remote alarm notification, audible (95dB @ 30cm), vibration, visible alarm (flashing bright red LEDs), and on-screen indication of alarm conditions
  • Additional diagnostic alarm and display message for low battery

Datalogging

  • Continuous datalogging with a three-month capacity (at one-minute intervals)
  • User-configurable datalogging interval (from 1 to 3600 seconds)

Communication and Data Download

  • Data Download and instrument set-up on PC via charging and PC comm. cradle
  • Data download via AutoRAE2 Automated Test and Calibration Station
  • Wireless data and status transmission via built-in RF modem (optional)

Wireless Network

RAE Systems Dedicated Wireless Network

Wireless Frequency

ISM license-free bands

Wireless Range (Typical)

300 feet (100 meters)

Operating Temperature

-4° to 131°F (-20° to 55°C)

Humidity

0% to 95% relative humidity (non-condensing)

Dust and Water Resistance

IP-65 rating for dust and water ingress protection (validated by an independent test laboratory)

Hazardous Area Approval

  • US and Canada: Class I, Division I, Groups A, B, C and D. T-code T4 Class I, Zone 0 A/Exia IIC T4
  • Europe: ATEX CE, Ex II 1g, Ex ia IIC Ga T4
  • China: Ex ia llC T4

CE Compliance

EMC directive: 2004/108/EC. R&TTE directive: 1999/5/EC. ATEX directive: 94/9/EC

Warranty

  • Two years on non-consumable components and CO, H2S, and O2 Sensors
  • One year on ll other sensors, battery, and other consumable parts