RAE Systems ToxiRAE 3 Single Gas Monitor
RAE Systems ToxiRAE 3 Single Gas Monitor
MODEL# PGM-1700
- 0.1ppm resolution on Hydrogen Sulfide (H2S) sensor
- Carbon monoxide (CO) sensor
- Can record STEL, TWA, high and low alarms
- Logs up to 10 events
- Water- and dust-resistant
- Audible, visual, and vibration alarm
This portable single-gas monitor is designed to keep workers safe against the threat of carbon monoxide (CO) and hydrogen sulfide (H2S). The ToxiRAE 3’s high-performance, three-electrode sensor delivers the fastest possible response time. When used with the AutoRAE Lite bump test and calibration station, it provides a low total cost of ownership (TCO) to organizations that are looking to protect workers and deliver worksite CO and H2S personal detection compliance. With its water and dust-resistant housing, and three-alarm capability, it’s a valuable tool for ensuring workers are aware of the presence of CO or H2S.
Gas | Range | Resolution |
---|---|---|
Hydrogen Sulfide (H2S) | 0 to 100 ppm | 0.1 ppm |
Carbon Monoxide (CO) | 0 to 500 ppm | 1 ppm |
Carbon Monoxide (CO), Ext. Range | 0 to 1999 ppm | 1 ppm |
Size | 3.4" L x 2.2" W x 0.8" H (8.6 cm x 5.5 cm x 2.0 cm) |
Weight | 3.5 oz (99 g) with battery |
Battery | User-replaceable 2/3 AA high-capacity lithium |
Alarms |
|
Data logging | 10 events |
Response Time | T90 < 12 seconds |
IP Rating | IP-67 |
EMI/RFI | Highly resistant to EMI/RFI. Compliant with EMC directive 2004/108/EC |
Certification |
|
Operating Temperature |
|
Humidity | 0 to 95% relative humidity (non-condensing) |
Warranty | 2 years, including sensors and battery if used within specs |
Calibration | Two-point calibration for zero and span |