RAE Systems MultiRAE Pro Multi-Gas Detector
MODEL# PGM-6248
- Over 30 interchangeable sensor options, including gamma radiation and parts-per-billion (ppb) PID
- Intelligent sensors store calibration data, so they can be swapped in the field.
- Continuous datalogging (6 months for 5 sensors, 24/7).
- Large graphical display with intuitive icon-driven user interface.
- Built-in pump, 250 cc/min average
The MultiRAE Pro is the industry’s first wireless multi-threat detection tool that combines continuous monitoring capabilities for gamma radiation, volatile organic compounds (VOCs) down to parts-per-billion level, toxic, combustible gases, and oxygen, with Man Down Alarm functionality in one highly portable instrument. Certified to meet the military performance standard MIL-STD-810F, the MultiRAE Pro can be configured with 33 intelligent sensors (including ppb and ppm PID, NDIR, and exotics such as ammonia, chlorine, formaldehyde, and phosgene) to fully meet the monitoring needs of applications such as HazMat response, CBRN / TIC / TIM detection, EOD, homeland security, and civil defense.
The instrument boasts the largest display and longest battery runtime in its class (with an optional extended battery), as well as an ergonomically contoured case that is rugged, dust-tight and waterproof (IP-65 / IP-67 rating). A compartmentalized design of the MultiRAE Pro makes the replacement of its sensors, pump, and plug-and-play battery simple, even in the field, and the AutoRAE 2 Automatic Test and Calibration System ensures bump testing and calibration of up to 10 instruments is as easy as a press of a button.
When deployed on RAE Systems’ Dedicated Wireless Network, the MultiRAE provides safety officers wireless access to real-time instrument readings and alarm status for better visibility and faster incident response. The MultiRAE five-way notification system for gas and Man Down alarms immediately alerts the user, people working in the vicinity, and safety officers at the command center if a hazardous atmosphere has been detected or a person has been overcome.
Sensor | Range | Resolution |
---|---|---|
Gamma | 0 to 20,000 microREM/h; 1 microREM to 4.29 REM (dose range) | 1 microREM/h |
VOC 10.6 eV (HR) | 0 to 5,000 ppm | 0.1 ppm |
VOC 10.6 eV (ppb) | 0 to 2,000 ppm | 10 ppb |
VOC 9.8 eV | 0 to 1,000 ppm | 0.1 ppm |
Catalytic LEL | 0 to 100% LEL | 1% LEL |
NDIR (0-100% LEL Methane) | 0 to 100% LEL | 1% LEL |
NDIR (0-100% Vol. Methane) | 0 to 100% Vol. | 0.1% Vol. |
Carbon Dioxide (CO2) NDIR | 0 to 50,000 ppm | 100 ppm |
Ammonia (NH3) | 0 to 100 ppm | 1 ppm |
Carbon Monoxide (CO) | 0 to 500 ppm | 1 ppm |
Carbon Monoxide (CO), Ext. Range | 0 to 2,000 ppm | 10 ppm |
Carbon Monoxide (CO), H2 - comp. | 0 to 2,000 ppm | 10 ppm |
Carbon Monoxide (CO) + Hydrogen Sulfide (H2S) Combo | 0 to 500 ppm CO / 0 to 200 ppm H2S | 1 ppm CO / 0.1 ppm H2S |
Chlorine (Cl2) | 0 to 50 ppm | 0.1 ppm |
Chlorine Dioxide (ClO2) | 0 to 1 ppm | 0.03 ppm |
Ethlyene Oxide (EtO-A) | 0 to 100 ppm | 0.5 ppm |
Ethylene Oxide (EtO-B) | 0 to 10 ppm | 0.1 ppm |
Ethylene Oxide (EtO-C), Ext. Range | 0 to 500 ppm | 10 ppm |
Formaldehyde (HCHO) | 0 to 10 ppm | 0.01 ppm |
Hydrogen (H2) | 0 to 1,000 ppm | 2 ppm |
Hydrogen Chloride (HCl) | 0 to 15 ppm | 1 ppm |
Hydrogen Cyanide (HCN) | 0 to 50 ppm | 0.5 ppm |
Hydrogen Sulfide (H2S) | 0 to 100 ppm | 0.1 ppm |
Hydrogen Sulfide (H2S) ext. range | 0 to 1,000 ppm | 1 ppm |
Methyl Mercapatan (CH3-SH) | 0 to 10 ppm | 0.1 ppm |
Nitric Oxide (NO) | 0 to 250 ppm | 0.5 ppm |
Nitrogen Dioxide (NO2) | 0 to 20 ppm | 0.1 ppm |
Oxygen (O2) | 0 to 30% Vol. | 0.1% Vol. |
Phosgene (COCl2) | 0 to 1 ppm | 0.02 ppm |
Phosphine (PH3) | 0 to 20 ppm | 0.1 ppm |
Phosphine (PH3) ex. range | 0 to 1,000 ppm | 1 ppm |
Sulfur Dioxide (SO2) | 0 to 20 ppm | 0.1 ppm |
Size | 7.6" H x 3.8" W x 2.6" D (193 x 96.5 x 66 mm) |
Weight | 31 oz. (880 g) |
Sensors | Over 30 intelligent interchangeable field-replaceable sensors including gamma radiation, ppb and ppm PID sensors for VOCs, electrochemical sensors for toxic gases and oxygen, combustible LEL and NDIR sensors, and CO2 NDIR sensor |
Battery |
|
Displays | Monochrome graphical LCD display (128 x 160) with backlighting. Automatic screen "flip" feature |
Keypads | 3 operation and programming keys (Mode, Y/+, and N/-) |
Sampling | Built-in pump. Average flow rate: 250 cc/min. Auto shutoff in low-flow conditions |
Calibration | Automatic with AutoRAE 2 Test and Calibration System1 or manual |
Datalogging |
|
Communication and Data Download |
|
Wireless Network | RAE Systems Dedicated Wireless Network |
Wireless Frequency | ISM license-free bands |
Wireless Range (Typical) | 656 feet (200 meters) |
Operating Temperature | -4° to 122°F (-20° to 50°C) |
Humidity | 0% to 95% relative humidity (non-condensing) |
Dust and Water Resistance | IP-65/IP-67 (when off) rating |
Direct Readout |
|
Alarms |
|
Hazardous Location Approvals |
|
CE Compliance (European Conformity) | EMC directive: 2004/108/EC. R&TTE directive: 1999/5/EC. ATEX directive: 94/9/EC |
EMI/RF | No effect when exposed to 0.43mW/cm2 RF interference from a 5-watt transmitter at 12" |
Performance Tests | LEL CSA C22.2 No. 152; ISA-12.13.01 |
Languages | Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, and Swedish |
Warranty |
|