Low Flow Sampling Controller
The Low Flow Sampling Controller is engineered specifically for the Cyclone, Mini-Typhoon, Typhoon, Tempest, Twister and Mini-Monsoon. The Low Flow Sampling Controller allows the user to precisely control the pump discharge flow to as low as 40 ml per minute. Simply connect the controller to a 12-volt battery and connect the pump to the controller. Set the control dial to low, turn on the controller, and then increase the flow to the desired rate.
Features
Weatherproof heavy-duty steel enclosure with handle
Low voltage disconnect at 11 volts (turns off controller at 11 volts to let user know that battery voltage is low and needs charging)
15-amp and 25-amp fuse to protect electronics and user
6-month parts and labor warranty under normal use
On/off switch and low flow control dial
Includes 3-foot wire lead with battery clamps and 3-foot wire lead with pump connector
|
 |
Econo Power Booster I
The Econo Power Booster I is engineered specifically for the Mega-Typhoon high performance pump. The Econo Power Booster I increases a 12-volt power supply to a constant 19 volts, increasing the performance of the Mega-Typhoon. Simply hook the Econo Power Booster I to a car battery and connect the Econo Power Booster I adapter to the pump and the booster will turn on automatically. This device is engineered for rapid purging of groundwater wells.
The Econo Power Booster I provides optimal performance when connected to a 12-volt vehicle battery while the engine is running. This will allow the vehicle's alternator to maintain the vehicle battery charge. If the engine is not running, or a stand-alone 12-volt battery is used, complete battery discharge may occur within 45-60 minutes of continual pump use.
Features
High impact black plastic case
Low voltage disconnect at 11 volts (turns off controller at 11 volts to let user know that battery voltage is low and needs charging)
Constant Voltage Booster (CVB) Technology allows constant voltage to reach the pump motors regardless of battery charge status
15-amp fuse to protect electronics and user
30-day parts and labor warranty
Green on/off indicator light
Includes 3-foot wire lead with battery clamps and 2-foot wire lead with pump connector
|
NOTE:
THIS DEVICE DOES NOT TOTALLY SHUT OFF THE PUMP MOTORS.
|
Power Booster I Controller
The Power Booster I Controller is engineered specifically for the Mega-Typhoon high performance pump. The Power Booster I Controller increases a 12-volt power supply to a constant 19 volts, increasing the performance of the Mega-Typhoon. Simply hook the Power Booster I Controller to a car battery and connect the Power Booster I Controller adapter to the pump, turn the controller on, and set the dial to the desired flow rate. This controller will not completely shut off power to the pump motors!
The Power Booster I Controller provides optimal performance when connected to a 12-volt vehicle battery while the engine is running. This will allow the vehicle's alternator to maintain the vehicle battery charge. If the engine is not running, or a stand-alone 12-volt battery is used, complete battery discharge may occur within 30-45 minutes of continual pump use.
Features
Weatherproof heavy-duty steel enclosure with handle
Low voltage disconnect at 11 volts (turns off controller at 11 volts to let user know that battery voltage is low and needs charging)
Constant Voltage Booster (CVB) Technology allows constant voltage to reach the pump motors regardless of battery charge status
25-amp fuse to protect electronics and user
6-month parts and labor warranty under normal use
On/off switch and flow control dial
Includes 3-foot wire lead with battery clamps and 3-foot wire lead with pump connector
|

NOTE:
THIS DEVICE DOES NOT TOTALLY SHUT OFF THE PUMP MOTORS.
|
Power Booster II Controller
The Power Booster II Controller is engineered specifically for the Tsunami, Hurricane, and Monsoon high performance pumps. The Power Booster II Controller increases a 12-volt power supply to a constant 19 volts, increasing the performance of the Tsunami, Hurricane, and Monsoon. Simply hook the Power Booster II Controller to a car battery and connect the Power Booster II Controller adapter to the pump, turn the controller on, and set the dial to the desired flow rate. This controller will not completely shut off power to the pump motors!
The Power Booster II Controller provides optimal performance when connected to a 12-volt vehicle battery while the engine is running. This will allow the vehicle's alternator to maintain the vehicle battery charge. If the engine is not running, or a stand-alone 12-volt battery is used, complete battery discharge may occur within 30-45 minutes of continual pump use.
Features
Weatherproof heavy-duty steel enclosure with handle
Low voltage disconnect at 11 volts (turns off controller at 11 volts to let user know that battery voltage is low and needs charging)
Constant Voltage Booster (CVB) Technology allows constant voltage to reach the pump motors regardless of battery charge status
25-amp fuse to protect electronics and user
6-month parts and labor warranty under normal use
On/off switch and flow control dial
Includes 3-foot wire lead with battery clamps and 3-foot wire lead with pump connector
|
 |
Low Flow with Power Booster I Controller
The Low Flow with Power Booster I Controller is engineered specifically for the Mega-Typhoon high performance pump. The Power Booster increases a 12-volt power supply to a constant 19 volts, increasing the performance of the Mega-Typhoon. The Low Flow Controller allows for pump rates as low as 40 ml per minute. Simply hook the Low Flow with Power Booster I Controller to a car battery and connect the Low Flow with Power Booster I Controller adapter to the pump, turn the controller on, and set the dial to the desired flow rate.
Features
Weatherproof heavy-duty steel enclosure with handle
Low voltage disconnect at 11 volts (turns off controller at 11 volts to let user know that battery voltage is low and needs charging)
Constant Voltage Booster (CVB) Technology allows constant voltage to reach the pump motors regardless of battery charge status
5-amp fuse to protect electronics and user
6-month parts and labor warranty under normal use
On/off switch and flow control dial
Includes 3-foot wire lead with battery clamps and 3-foot wire lead with pump connector
|
 |
Low Flow with Power Booster II Controller
The Low Flow with Power Booster II Controller is engineered specifically for the Tsunami and Monsoon high performance pumps. The Power Booster increases a 12-volt power supply to a constant 24 volts, increasing the performance of the Tsunami and Monsoon. The Low Flow Controller allows for pump rates as low as 40 ml per minute. Simply hook the Low Flow with Power Booster II Controller to a car battery and connect the Low Flow with Power Booster II Controller adapter to the pump, turn the controller on, and set the dial to the desired flow rate.
Features
Weatherproof heavy-duty steel enclosure with handle
Low voltage disconnect at 11 volts (turns off controller at 11 volts to let user know that battery voltage is low and needs charging)
Constant Voltage Booster (CVB) Technology allows constant voltage to reach the pump motors regardless of battery charge status
25-amp fuse to protect electronics and user
6-month parts and labor warranty under normal use
On/off switch and flow control dial
Includes 3-foot wire lead with battery clamps and 3-foot wire lead with pump connector
|
 |
Low Flow with Power Booster III Controller
The Low Flow with Power Booster III Controller is engineered specifically for the Mega-Monsoon high performance pump. The Power Booster increases a 12-volt power supply to a constant 24 volts, increasing the performance of the Mega-Monsoon. The Low Flow Controller allows for pump rates as low as 40 ml per minute. Simply hook the Low Flow with Power Booster III Controller to a car battery and connect the Low Flow with Power Booster III Controller adapter to the pump, turn the controller on, and set the dial to the desired flow rate.
Features
Weatherproof heavy-duty steel enclosure with handle
Low voltage disconnect at 11 volts (turns off controller at 11 volts to let user know that battery voltage is low and needs charging)
Constant Voltage Booster (CVB) Technology allows constant voltage to reach the pump motors regardless of battery charge status
50-amp fuse to protect electronics and user
6-month parts and labor warranty under normal use
On/off switch and flow control dial
Includes 4-foot wire lead with battery clamps and 4-foot wire lead with pump connector |
|