DRT-15CE PORTABLE TURBIDIMETER
Designed to provide the rugged portability needed in the field with the accuracy demanded in the laboratory, the EPA approved* DRT-15CE has become a "must have" for anyone monitoring turbidity on the go. The integral carrying case holds everything needed for field operation. With resolution of 0.01 NTU and an extended range to 1,000 NTU, the DRT-15CE is a perfect fit for both field and laboratory use. |
Buy This Product
STANDARD FEATURES:
Rugged Portable Carrying Case
Ensures durability and convenience no matter where your laboratory happens to be.
Completely Self-Contained
Provides easy access to everything you need to take a measurement.
Three User Selectable Ranges
Provides accuracy in a wide variety of applications from 0 to 1000 NTU.
20 Hour Rechargeable Battery
Always be ready to go with up to 20 hours of continuous operation when fully charged.
Made in the USA
OPTIONAL FEATURES:
Automobile Adapter
Charge and operate the DRT-15CE from the cigarette lighter in your automobile.
Formazin Stock Solution Kit
Contains everything you need to calibrate the DRT-15CE with Formazin, the primary calibration standard.
|
|
|
Includes battery charger, sample cuvette with light shield cap, 0.2 NTU reference standard, recorder output plug and instruction manual.
* The DRT-15CE exceeds performance criteria specified by US EPA method 180.1 for NTU measurement |
|
|
SPECIFICATIONS |
Range: |
0 - 10 NTU 0 - 100 NTU 0 - 1000 NTU |
Accuracy: |
0-10 NTU, ± 1% of full scale
0-100 NTU, ± 5% of full scale
0-1000 NTU, ± 10% of full scale |
Resolution: |
0.1% of selected range |
Response Time: |
Immediate |
Sample Size: |
25 ml (16 ml minimum) |
Operating Temperature: |
32° - 122°F (0° - 50°C) |
Battery: |
6V gel-cell rechargeable with 20 hours of continuous use when fully charged. |
Recharge Time: |
8 hours to full charge |
Dimensions: |
11 x 8 x 5 - inches (28 x 20 x 14 cm) |
Weight: |
5 lbs (2.27 kg) |
Standards Compliance: |
USEPA, CE Approved |
|
DRT-15CE Instruments and Accessories
Catalog Number |
Description |
|
Instruments |
19057 |
Portable Turbidimeter (0 - 1000) NTU (120V) |
19058 |
Portable Turbidimeter (0 - 1000) NTU (240V) |
|
Note: Both of above include a battery charger, sample cuvette with light shield cap, 0.02 NTU reference standard, recorder output plug, and instruction manual. |
|
Accessories |
20115 |
Adapter Kit, 16mm factory installed |
19045 |
Auto Adapter 12 Volt |
70050 |
Battery Charger - 120V |
19046 |
Battery Charger - 240 V European Standard |
| |
|
|
|
29071 |
PrimeTime Calibration Set (0.02, 10, 100, & 1000 NTU) |
| |
|
|
|
50048 |
Cuvette 16mm 3/pk. with cap shields (requires adapter, catalog no. 20115) |
50052 |
Cuvette 28 x 70mm 10/pk. (replaces 28 x 93mm) Use for grab sample. Includes 10 threaded light shield caps. |
50051 |
Cuvette 28 x 70mm 3/pk. (replaces 28 x 93mm) Use for grab sample. Includes threaded light shield caps. |
19981 |
Cuvette Stand for storing empty cuvettes as well as calibration standards; holds up to 11 cuvettes. |
| |
|
|
|
50040 |
Formazin Stock Solution Kit. Each kit contains 32 ounces of 4000 NTU Formazin, one gallon 0.02 NTU water, one 0.02 NTU Reference Standard, four cuvettes with indexing light shields, three pipettes, and instruction manual. |
21805 |
Instruction Manual |
50009 |
Light Shield (not threaded for use with 28 x 93mm cuvettes) |
19975 |
Pour Through Assembly (includes the assembly, locking ring, 24" of drain tubing, cuvettes and instructions) |
70008 |
Rechargeable Battery |
60002 |
Reference Standard 0.02 NTU (Complete with indexing light shield.) |
21084 |
Source Lamp Assembly, 2/pk. |
|