Description |
RF2 |
RF4 |
Part I |
Rated Power & Markings |
Input Voltage |
1 X 115V +/- 10% or 1 X 230V +/- 10%
Single Phase Input |
Output Voltage |
3 X 220V |
3 X 230V |
Continuous Output Current (230V input) |
6.05A |
8.25A |
Continuous Output Current (115V input) |
6.05A |
6.50A |
Part II |
Fundamental Parameters |
Control System |
PWM |
Output Voltage |
Clamp @ 220V |
Clamp @ 230V |
Carrier Freq. |
Selectable: 1-5 KHz |
Freq. Resolution |
0.1Hz* |
Input Freq. Range |
48 – 62 Hz |
Maximum Output Frequency(230V input) |
400 Hz |
100 Hz |
Maximum Output Frequency(115V input) |
400 Hz |
80 Hz |
Base Frequency |
400 Hz |
100 Hz |
Torque Boost |
0 – 15% Nominal Voltage |
V/F Pattern |
Selectable Linear/Square Law |
Accel Time |
0.5 – 3600 Seconds |
Decel Time |
0.5 – 3600 seconds |
Accel/Decel Pattern |
Linear |
Part III |
Protective Functions |
Ground Fault |
Ground Fault detection for Equipment Protection |
Overcurrent |
Output Short Circuit
Locked Rotor |
Over Voltage |
400VDC |
Under Voltage |
200VDC |
Motor Overload |
I2 x T Characteristic |
Line Start Lock Out |
VFD will not start upon input power application |
Line Transient Rating |
860 VAV, 810J MOV Between any power
input terminal & Ground
360 VAC, 380 J MOV Between any two
power input terminals |
Part IV |
Ambient Operating Conditions |
Operating Temp. |
-10 to 40 degree C |
Storage Temp. |
-30 to 65 degree C |
Vibration |
0.5G, Max / 57-150 Hz |
Elevation |
3300 ft. without derating |
Max source fault current |
5 Kamps |
Enclosure rating |
UL Type 4, No Direct Sunlight |