| Specifications
The CR:100B doseBadge Personal Noise Dosimeter and the RC:100B Reader Unit have been designed to meet the requirements of IEC 61252:1993 Personal Sound Exposure Meters and the ANSI S1.25:1991 Personal Noise Dosimeters. The CR:100B doseBadge and the RC:100B Reader unit must be used as a combination to ensure compliance with these standards.
Applicable Standards
IEC 61252:1993 Personal Sound Exposure Meters (See Note 1)
ANSI S1.25:1991 Personal Noise Dosimeters Class Designation 2AS-90/80-5 (See Note 2)
Note 1. When configured to the ISO Setting
Note 2. When configured to the OSHA Setting
Measurement Range
80dB(A) to 130dB(A) Continuous
To 140dB(C) Peak (factory configured to 140dB, 137dB or 134dB)
Measurement Functions
All versions doseBadge configuration, Calibration Record, Measurement Duration
Peak Exceedence ,Overload Exceedence, Battery Status
1 minute or 5 minute Time History (user selectable)
The Time History is stored as LAeq along with a Peak(C) Exceedence and Overload in each period. The duration of the Time History is configured in the RC:100B Reader Unit.
For ISO Q=3 LAeq, LEP,d, SEL, % Dose, Exposure (Pa2h), Estimated % Dose,
Estimated Exposure (Pa2h)
For OSHA Q=5 LAVG,TWA, % Dose, Estimated % Dose
Memory
The memory of the RC:100B Reader is 192kB. This allows the following number of measurements to be stored:
No Time History Up to 500 Measurements
With 24 hours of 1 minute Time History Up to 66 Measurements
With 12 hours of 1 minute Time History Up to 128 Measurements
With 8 hours of 1 minute Time History Up to 186 Measurements
Weightings
Frequency 'A' for all Sound Level measurements. 'C' for Peak Sound Pressure
Time None as standard. 'S' (slow) for OSHA Version
Exchange Rate
Q=3 for ISO Version
Q=5 for OSHA Version
doseBadge Configuration
Criterion Level User Selectable 80dB, 85dB, 87dB, 90dB
Criterion Time 8 hours, 12 hours, 16 hours, 18 hours
Threshold None (ISO), 80dB (OSHA)
Peak Threshold Factory configured to 140dB. 137dB(C) or 134dB(C) Peak Option
Power
doseBadge Internal Nicad battery with intelligent charging system
Reader 2 x AA/LR6
Memory Backup
The memory of the RC:100B Reader is protected when the main batteries are removed.
Calibration
Via internal Acoustic Calibrator to IEC 61942:1998 Class 1L
Calibration Level 114dB
Calibration Frequency 1kHz
Output
doseBadge Infrared to RC:100B Reader Unit
Reader RS232 via Mini-Din
Dimensions
doseBadge Microphone Apex 12.7mm, Base 47mm, Height 30mmm
RC:100B Reader 160mm x 80mm x 38mm
Environmental
Temperature -10C to +50C Operating
-20C to +60C Storage
Humidity Up to 99% RH Non Condensing
Weight
CR:100B 45 gms (1.6 oz)
RC:100B Reader 400 gms (14 oz)
Software
The dBLink Download program and the doseBadge Database supplied as standard. Compatible with Microsoft Windows versions 95 or later. A free 9 pin RS232 Serial port is required on the PC for connection to the Reader. A USB Adaptor is available (ZL:101).
Individual Components
The individual components can be ordered separately, for example when expanding a kit with more doseBadges. The components are: |