RAE Systems CO (H2 Compensated) Sensor C03-0979-000
RAE Systems CO (H2 Compensated) Sensor C03-0979-000
Sensor Type | Electrochemical |
Range | 0 to 2,000 ppm |
Max Overload | 4,000 ppm |
Resolution | 1 ppm |
Bias/Equilibration | No bias / 10 min. after installation |
Temperature Range | -4° F to 122° F (-20° C to 50° C) |
Pressure Range | Atmospheric ±10% |
Operating Humidity | 15 to 90% RH non-condensing |
Drift | < 1% signal/month |
Storage Life | 6 months in sealed container |
Storage Temperature | 32° F to 68° F (0° C to 20° C) |
Operating Life | 1 year in air |
Warranty | 1 year from date of shipment |
Calibration Gas | 100 ppm CO, balance Air |